ROHDE & SCHWARZ FSP3 REPAIR and ROHDE & SCHWARZ FSP3 CALIBRATION

 
Custom-Cal has a high success rate in the repair of the ROHDE & SCHWARZ FSP3. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the ROHDE & SCHWARZ FSP3 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another RF Spectrum Analyzer?
Shop for Comparable Products on our
 used RF Spectrum Analyzer page or new RF Spectrum Analyzer page

 
   ROHDE & SCHWARZ FSP3 (1164.4391.03)   Description / Specification:    
ROHDE & SCHWARZ FSP3 3 GHz Spectrum Analyzer

The R&S FSP3 (1164.4391.03) 3 GHz Spectrum Analyzer is the ideal partner in development and production, featuring low uncertainty in level measurement, as well as excellent RF characteristics. Resolution bandwidths of up to 100 kHz are fully digital and provide – in addition to high selectivity – an ideal basis for accurate (adjacent-) channel power measurements owing to a maximum bandwidth deviation of 3%. The R&S FSP3 comes equipped with digital resolution filters between 10 Hz and 100 kHz featuring high selectivity and very low bandwidth deviation. The filters have an extremely low logarithmic level deviation of <0.2 dB in the range 0 dB to –70 dB. As they are implemented as ASIC functions, their great precision is attained without any reduction in measurement speed. A unique RMS detector measures modern, noise-like communication signals with optimal repeatability and stability. Specifications. Frequency range: 9 kHz to 3 GHz. Reference frequency aging: 1 x 10^–6/year; with option R&S FSU-B4: 1 x 10^–7/year. Phase noise: typ. –113 dBc (1 Hz) at 10 kHz from carrier. Residual FM: 3 Hz. Sweep time: 2.5 ms to 16000 s (Span >=10 Hz), 1 µs to 16000 s (Span 0 Hz (zero span)). Resolution bandwidth: 10 Hz to 10 MHz, FFT filter; 1 Hz to 30 kHz, channel filter, EMI bandwidths. Video bandwidths: 1 Hz to 10 MHz. Display range: displayed average noise level up to +30 dBm. Displayed average noise level: typ. –148 dBm (1 GHz). Displayed average noise level with optional on (option FSP-B25 electronic attenuator on): –152 dBm. Total measurement error, f < 3 GHz: 0.5 dB. Linear level display: 0.2 dB (0 dB to –70 dB). Options. FSP-B3 (1129.6491.02), AM/FM Audio Demodulator. FSP-B4 (1129.6740.02), OCXO Reference Frequency. FSP-B6 (1129.859.4.02), TV Trigger/RF Power Trigger. FSP-B9 (1129.6991.02), Internal Tracking Generator 9 kHz to 3 GHz, I/Q modulator. FSP-B10 (1129.7246.03), External Generator Control. FSP-B15 (1155.1006.02), Pulse Calibrator. FSP-B16 (1129.8042.03), LAN Interface 100BT. FSP-B18 (1163.0892.03), Removable Flash Disk. B19 (1163.1124.03), Second Flash Disk. FSP-B21 (1155.1758.03), LO/IF Ports for External Mixers. FSP-B25 (1129.7746.03), Electronic Attenuator, 0 dB to 30 dB, 5 dB steps, integrated preamplifier. FSP-B28 (1162.9915.02), Trigger Port for indication of trigger conditions. FSP-B29 (1163.0663.07), Frequency Range Extension 20 Hz. FSP-B70 (1157.0559.02), Demodulation Hardware and Memory Extension.



 

Standard Calibration $700.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the ROHDE & SCHWARZ FSP3. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related RF Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Clipping
Clipping is the limiting of a signal so that it never exceeds some threshold.

Modulation
Modulation is the coding of information onto the carrier frequency. This includes amplitude, frequency, or phase modulation techniques.

Sensitivity
Sensitivity is the smallest signal that can reliably detected. Sensitivity specifies the strength of the smallest signal at the input that causes the output signal power to be M times the output noise power where M must be specified. M=1 is very popular


Please contact us for your ROHDE & SCHWARZ FSP3 REPAIR and/or ROHDE & SCHWARZ FSP3 3 GHz Spectrum Analyzer CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: